Stay Updated
Menu

Product Strengths

Available in two dosage strengths1

VONVENDI® [von Willebrand factor (Recombinant)] is available as a non-pyrogenic lyophilized powder for reconstitution in single-use vials containing nominally 650 or 1300 international units VWF:RCo per vial.

The actual von Willebrand factor activity in international units is printed on the label of each VONVENDI vial for easy identification.

Storage & handling of VONVENDI1

  • Store at refrigerated temperature 2°C to 8°C (36°F to 46°F) or room temperature not to exceed 30°C (86°F).
  • Do not freeze.
  • Store in the original box and protect from extreme exposure to light.
  • Do not use beyond the expiration date printed on the VONVENDI vial label or carton.
  • Use reconstituted product immediately or within 3 hours after reconstitution.
  • Discard any unused reconstituted product after 3 hours.
Image depicting the two available dosage strengths for VONVENDI

Representative Finder

Your local Shire representative is happy to help answer your questions about VONVENDI®

Stay Updated

Stay up to date with the latest news and information

See LessMore

Indications VONVENDI [von Willebrand factor (recombinant)] is a recombinant von…

Detailed Important Risk Information Do not use VONVENDI in patients who have had life-threatening hypersensitivity reactions…

Indications

VONVENDI [von Willebrand factor (recombinant)] is a recombinant von Willebrand factor (rVWF) indicated for use in adults (age 18 and older) diagnosed with von Willebrand disease (VWD) for:

  • On-demand treatment and control of bleeding episodes
  • Perioperative management of bleeding

Detailed Important Risk Information

CONTRAINDICATIONS

Do not use VONVENDI in patients who have had life-threatening hypersensitivity reactions to VONVENDI or its components (tri-sodium citrate-dihydrate, glycine, mannitol, trehalose-dihydrate, polysorbate 80, and hamster or mouse proteins).

VONVENDI® [von Willebrand factor (recombinant)] Important Information

Indications

VONVENDI [von Willebrand factor (recombinant)] is a recombinant von Willebrand factor (rVWF) indicated for use in adults (age 18 and older) diagnosed with von Willebrand disease (VWD) for:

  • On-demand treatment and control of bleeding episodes
  • Perioperative management of bleeding

Detailed Important Risk Information

CONTRAINDICATIONS

Do not use VONVENDI in patients who have had life-threatening hypersensitivity reactions to VONVENDI or its components (tri-sodium citrate-dihydrate, glycine, mannitol, trehalose-dihydrate, polysorbate 80, and hamster or mouse proteins).

WARNINGS AND PRECAUTIONS

Embolism and Thrombosis

Thromboembolic reactions, including disseminated intravascular coagulation, venous thrombosis, pulmonary embolism, myocardial infarction, and stroke, can occur, particularly in patients with known risk factors for thrombosis, including low ADAMTS13 levels. Monitor for early signs and symptoms of thrombosis such as pain, swelling, discoloration, dyspnea, cough, hemoptysis, and syncope, and institute prophylaxis measures against thromboembolism based on current recommendations.

In patients requiring frequent doses of VONVENDI in combination with recombinant factor VIII, monitor plasma levels for FVIII:C activity because sustained excessive factor VIII plasma levels can increase the risk of thromboembolic events.

One out of 80 VWD patients treated with VONVENDI in clinical trials developed proximal deep vein thrombosis in perioperative period after undergoing total hip replacement surgery.

Hypersensitivity Reactions

Hypersensitivity reactions, including anaphylaxis, may occur. Symptoms can include anaphylactic shock, generalized urticaria, angioedema, chest tightness, hypotension, shock, lethargy, nausea, vomiting, paresthesia, pruritus, restlessness, wheezing and/or acute respiratory distress. Discontinue VONVENDI if hypersensitivity symptoms occur and administer appropriate emergency treatment.

Neutralizing Antibodies (Inhibitors)

Inhibitors to von Willebrand factor and/or factor VIII can occur. If the expected plasma levels of VWF activity (VWF:RCo) are not attained, perform an appropriate assay to determine if anti-VWF or anti-factor VIII inhibitors are present. Consider other therapeutic options and direct the patient to a physician with experience in the care of either VWD or hemophilia A.

In patients with high levels of inhibitors to VWF or factor VIII, VONVENDI therapy may not be effective and infusion of this protein may lead to severe hypersensitivity reactions. Since inhibitor antibodies can occur concomitantly with anaphylactic reactions, evaluate patients experiencing an anaphylactic reaction for the presence of inhibitors.

ADVERSE REACTIONS

In clinical trials, the most common adverse reactions observed in ≥2% of subjects (n=80) were generalized pruritus, vomiting, nausea, dizziness and vertigo.

One subject treated with VONVENDI in perioperative setting developed deep vein thrombosis after undergoing total hip replacement surgery.

Please see VONVENDI full Prescribing Information.